AETEC Private Limited

Robotic Materials Test Cell

Simulator ModeAEOS IPC DisconnectedPhysical Cell DisengagedLocal Simulator DBwww.aetec.net
SIMULATOR
Digital-twin sessionNo physical robot, test machine or AEOS industrial PC is being commanded.
Actual robot: DISENGAGEDAEOS IPC: DISCONNECTEDLocal simulator: READY
Incoming
40
Coupons remaining
Vision Inspected
0
Front and rear captures
Mechanically Tested
0
Completed test records
Pass / Outgoing
0
Sorted to green tray
Reject
0
Vision or test reject
Simulator Records
0
Local demo reports stored
Interactive robotic test-cell simulation

3D Simulator

TENSILE TEST
Cell ready — start a cycle or automatic batch
Vacuum pick, QR scan, vision inspection, fixture I/O and database traceability are ready.
3D DIGITAL TWIN SIMULATOR
Orbit · pan · zoom · full screen
Upper clampOPEN
Lower clampOPEN
VacuumOFF
Collision monitorCLEAR
Idle0%
Live and completed test data

Stress–Strain Curve

Live Force0.00 kN
Live Stress0.0 MPa
Live Strain0.00 %
ResultPending
Measured / simulated resultMaterial reference curve
Comprehensive specimen record

No test selected

PENDING
Incoming AI Vision InspectionNo inspection record
Automatic Acceptance CheckNo database record
Batch traceability

Batch Results & Audit Trail

Completed Results0 / 40 records
Event Log0 events
Serial I/O Log0 records
AEOS edge integration

Connectivity & Device Registry

Prepare the secure standby link between this web application, the AEOS software on the standalone industrial PC and the devices inside the material test cell.

SIMULATOR PROFILEAEOS NOT LINKED
Web ApplicationONLINESimulator user interface
Application DatabaseLOCAL DEMOBrowser / demo API records
AEOS Industrial PCDISCONNECTEDStandby adapter prepared
Physical Test CellDISENGAGEDNo live command channel
Vision AI RuntimeDISCONNECTEDIPC model not reachable
Simulator-safe configuration

AEOS Link Profile

NOT PAIRED
Security boundaryCredentials, private keys and machine-control logic are not stored in the browser. The live system uses an authenticated AEOS edge service and local safety controls.
Logical data path

Secure Link Topology

STANDBY
WEBWeb AppUI · reports · academy
APICloud Servicesidentity · database · jobs
IPCAEOS Edgedisconnected in simulator
AEOS Device AgentDISCONNECTED
Material Test Machine AdapterSTANDBY
Robot Status AdapterSTANDBY
Serial I/O / PLC AdapterSTANDBY
Vision & QR AdapterSTANDBY
Local Result Database AdapterSTANDBY
Live operating principleThe browser requests data through the application API. AEOS maintains the edge session, reads the local devices and database, and keeps all motion and safety decisions inside the cell.
Cell assets

Device Registry

Device Device ID Interface Configured Address Revision Simulator State Live State
Data contract

AEOS Data Channels

Connection diagnostics

Standby Check Log

NOT RUN
Awaiting simulator-safe standby check.
Remote records

Data & Vision Archive

Review coupon records, front/rear images, AI findings, test results and model revisions. The simulator reads local demo records; the live view is supplied by AEOS.

SIMULATOR DATAREMOTE IPC OFFLINE
Visible Records12Demo and simulator results
Images Available24Front and rear captures
Needs Review4Potential defects
AEOS SourceOFFLINELocal archive shown
Image and result search

Archive Filters

Remote image browser

Coupon Inspection Images

LOCAL DEMO
Selected record

Select an image

NO SELECTION
AEOS database view

Result & Image Index

LIVE QUERY DISCONNECTED
Coupon ID Lot Material Test Result Vision AI Revision Timestamp Source
Defect detection lifecycle

AI Academy

Review inspection images, create defect annotations, version the dataset, launch a training job, compare model metrics and queue a signed model package for deployment to the AEOS industrial PC.

ACADEMY SIMULATIONIPC DEPLOYMENT OFFLINE
Dataset VersionDS-2026.06-R3Working annotation set
Labeled Images168Approved annotations
Review Queue12Images awaiting review
Production Model2.3.1Selected in simulator
AEOS RuntimeOFFLINEDeployment will be queued
Human-in-the-loop review

AET-DB-007 · FRONT

Drag over the coupon image to mark a potential defect. Gauge-section defects are treated as critical.
Annotation metadata

Defect Label

PENDING
Annotations1
AI predictionSCRATCH · 94.2%
Human decisionPENDING
Stored recordImage ID, QR ID, lot, camera, AI revision, label geometry, reviewer and timestamp are versioned together.
Dataset packaging

Training Configuration

READY
Ready to create a training job0%
Precision
Recall
mAP50
mAP50–95
Model governance

Model Registry

3 MODELS
Revision Dataset Precision Recall mAP50 Status
AEOS target stateDISCONNECTED
Last deploymentAE-VISION-2.3.1 · ACTIVE
Pending packageNONE
Auditability

Training & Deployment Jobs

Job ID Type Dataset / Model Target Status Created Detail